Basic Info.
Appliance
The Analysis of Environmental Samples
Ray Type
X-Ray Spectrometer
Spectrometer Detector
SDD
Stationary Phase
Solid Adsorbent
Chromatography Type
Liquid Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
2~5mm
Flow Range
0.001ml / Min ~ 10.000ml / Min
Wavelength Range
170nm ~ 900nm
Wavelength Repeatability
± 0.1nm
Wavelength Accuracy
± 1nm
Baseline Noise
≤2 × 10-5au
Baseline Drift
≤4 × 10-4au / Hr
Minimum Detectable Concentration
≤1 × 10-9g / Ml
Transport Package
Cartons
Specification
260mm × 360mm × 170mm
Product Description
Features:
LC-204 high-voltage constant-current pump features
LC-204 dual-piston high-pressure pump is a constant series reciprocating Heng Flow pump, high flow accuracy; l subdivision stepping motor control technology allows the motor to run at low speed
Smooth and accurate, to improve the accuracy and repeatability of analytical results at low flow rates, effectively ensuring the high-pressure gradient system
Under low flow systems and mobile phase composition stability;
The key component installation guide l floating plunger rod, plunger rod and a selection of high-quality seals, etc.
To ensure that the constant high pressure infusion pump long running stability and durability;
mobile phase compressibility factor correction and flow calibration accuracy dual function, depending on the solvent system differences
Error compensation in flow velocity within ± 15% range, ensuring a high flow accuracy;
via RS-485 chromatography workstation external control can be easily obtained with high accuracy high-pressure gradient
Of the system, while the mobile phase velocity gradient can be achieved to meet the various requirements of production and research;
Real-time pressure monitoring display, high pressure limit, low limit alarm function to ensure the safety of equipment used;
large flow flushing solvent substitution function, reducing the solvent displacement time, improve work efficiency;
with an OLED display module, friendly interface, easy and flexible operation.
Performance analysis of LC-4000 pump technical indicators
Flow Range: 0.001mL / min ~ 10.000mL / min (step is set to 0.001mL / min)
Flow accuracy: ≤ ± 1% (1.000mL / min, 8.5MPa, water, room temperature)
Flow Stability: RSD≤0.25%
Maximum working pressure: 43MPa (0.001mL / min ~ 10.000mL / min)
Pressure fluctuation: <0.1MPa (flow 1mL / min, pressure 5MPa ~ 10MPa)
Power: AC 110V / 220V, 50Hz / 60Hz
Power consumption: 100W
Dimensions (L × W × H): 260mm × 360mm × 170mm / 10.0kg
LC-204 variable wavelength UV / visible spectrophotometric detector
Instrument features
l advanced optical cell design;
Detector optical system into the new design ideas. As we know, the UV detector principle is Based on the Lambert - Beer law, so we focus on the improvement of the optical path above the road and so the sample is located
The reference light path of light for maximum battery power. SEV UV501 detector is designed with today's most advanced technology Surgery for the pilot, through digital data processing and control, so that baseline noise and drift down to a new Limit. As a result of the digital output function, the detector can be connected to a computer via serial port directly Without the need for any of the data acquisition unit.
Wherein, I1 is the sample path light intensity, I0 is the intensity of the reference light path, ε is the molar extinction coefficient, L is the flow Cell path.
Key improvements:
1) light source 2) optical path
Filter 3) new design 4) use holographic grating
l The new flow cell;
l the whole digital signal processing and control system;
l Integrated voltage integrated new design to make a more stable power supply, suitable for explosion-proof occasions.
Technical Parameters
Wavelength range: 170nm ~ 900nm
Wavelength repeatability: ± 0.1nm
Wavelength accuracy: ± 1nm
Band width: 6nm
Baseline noise ≤2 × 10-5AU (methanol, 1ml / min, 254nm, 20 ºC)
Baseline drift ≤4 × 10-4AU / hr (methanol, 1ml / min, settling time 60min, 254nm, 20 ºC)
Baseline noise ≤0.5 × 10-5AU (empty pool, response time 1 second, 20 ºC)
Baseline drift ≤0.5 × 10-4AU / hr (empty pool, 1 second response time, settling time 60min, 20 ºC)
The minimum detectable concentration ≤1 × 10-9g / ml (naphthalene / methanol solution)
Flow cell volume: 10μL
Optical path: 5mm
Source: Deuterium lamp
Power: AC 110V / 220V, 50Hz / 60Hz
Power consumption: 100W
Dimensions (L × W × H): 260mm × 360mm × 170mm / 10.0kg
Enhanced performance liquid chromatography |
Flow Range | 0.001mL / min ~ 10.000mL / min |
Wavelength range | 170nm ~ 900nm |
Wavelength repeatability | ± 0.1nm |
Wavelength accuracy | ± 1nm |
Band width | 6nm |
Baseline noise | ≤2 × 10-5AU |
Baseline drift | ≤4 × 10-4AU / hr |
minimum detectable concentration | ≤1 × 10-9g / ml |
Address:
The 9th Floor, District A, Liancheng Waiking Street, Jianshe Road, Yuetang, Xiangtan, Hunan, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Health & Medicine, Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 14064, GMP
Company Introduction:
As professional laboratory equipment manufacturer, we are in line with experimental equipment for many years, such as Vapor Permeability Tester, Gas permeation rate tester, drying oven, testing machine, Purification equipments, Geology testing, ICP&DRS, etc. <br><br>We have 20 years eexperience in this industry. We have sophisticated technology to serve for enterprise, scientific research institution, universities and colleges, etc. We cooperate with many research institution and university, etc. <br><br>Our product is widely used in Europe, North America, Asia, Africa, Latin America, etc. We have branches in hunan, and HK. We are paying attention to service and improving our product these years. Customer is everything, which is our service aim; All of our efforts are focused on providing the suitable testing instruments with reliable results. We believe that high quality and good service will pay important role in the future. <br><br>We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with the good quality at the reasonable price. <br><br>We have persisted on the business idea of "Integrity Basis and Quality First" for the stable and constant development. We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity. Client, quality and service are our supreme target!